Nominal DC Input Voltage | 48VDC |
Continuous Output Power (@25°C) | 8000VA |
AC Output Voltage (Selectable) | 120/240VAC |
AC Output Frequency (Selectable) | 60Hz (50Hz) |
Continuous AC Output Current (@25°C) | 33.3AAC @ 240VAC |
Idle Consumption (Invert Mode, No Load) | 34W |
Typical Efficiency | 92.5% |
CEC Weighted Efficiency | 92.5% |
Total Harmonic Distortion | Max. Total Harmonic: <5%; Max. Single Voltage Harmonic: <2% |
Output Voltage Regulation | +/- 2% |
Maximum Output Current | 1ms Peak: 100AAC @ 240VAC, 200AAC @ 120VAC; 100ms RMS: 70.7AAC @ 240VAC |
Overload Capacity | 100ms Surge: 16.97kVA; 5 seconds: 12kVA; 30 minutes: 9kVA |
AC Input Voltage Range (Adjustable) | (L1 or L2) 70 to 280VAC |
AC Input Frequency Range (Default) | 54 to 66Hz @ 60Hz (45 to 55Hz @ 50Hz) |
Grid-Interactive Voltage Range | (L1-N or L2-N) 106 to 132VAC, default |
Grid-Interactive Frequency Range | 59.3 to 60.5Hz, default |
Maximum AC Input Current | 50AAC |
Continuous Battery Charge Output | 115.0ADC |
DC Input Voltage Range | 40 to 64VDC |
Temperature Range | Rated: -20 to 50°C (power derated above 25°C); Maximum: -40 to 60°C :C ) M8
.
|
Accessory Ports | Remote Temperature Sensor, MATE3 & HUB Communications |
Non-Volatile Memory | Yes |
Field Upgradable Firmware | Yes |
Chassis Type | Vented |
Certifications | Listed to UL1741, CE, CSA C22.2 No. 107.1, IEC 62109-1, AS4777.2, AS4777.3, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3, AS3100, RoHS compliant per directive 2011/65/EU |
Warranty | Standard 5 year |
Weight (lb/kg) | Unit: 125.0/56.7; Shipping: 140.0/63.5 |
Dimensions H x W x D (in/cm) | Unit: 28 x 16 x 8.7 / 71 x 40.6 x 22.1; Shipping: 34.5 x 21 x 14.5 / 87.6 x 53.3 x 36.8 |