The Grundfos MAGNA3 32-100 GF N (product number 98126826) is a variable-speed ECM circulator for hydronic heating, cooling and domestic hot-water systems, delivering up to 32.81 ft of head and 29.1 US gpm. Its permanent-magnet motor and integrated controller give an energy efficiency index of EEI 0.18 — well inside the 0.23 ErP benchmark, and a fraction of the draw of a fixed-speed circulator. Power input modulates from 9.7 W to 178 W with demand.
Performance & Hydraulic Data
| Maximum head | 32.81 ft |
| Nominal flow | 29.1 US gpm |
| Nominal head | 20.67 ft |
| Maximum speed | 4557 rpm |
| Maximum operating pressure | 174.05 psi |
| Pipe connection pressure rating | PN 12 |
| Energy efficiency index (EEI) | 0.18 |
Performance Curve
Official Grundfos curve — 60 Hz, water at 68 °F.
Motor & Electrical Data
| Rated voltage | 115-230 V |
| Phase | 1 |
| Frequency | 60 Hz |
| Maximum power input (P1) | 178 W |
| Minimum power input (P1) | 9.7 W |
| Maximum rated current | 1.61 A |
| Minimum rated current | 0.29 A |
| Insulation class | F |
| Enclosure class | IPX4D |
| TF class | 110 |
Materials of Construction
| Pump housing | Stainless steel — EN 1.4308 — ASTM A351-CF8 |
| Impeller | Composite |
Connections & Operating Limits
| Pipe connection | GF15/26/40/43 |
| Connection type | GF |
| Port-to-port length | 6 1/2 in |
| Liquid temperature range | 14 to 230 °F |
| Ambient temperature range | 32 to 104 °F |
Dimensional Drawing
Approvals, Weights & Identification
| Grundfos product number | 98126826 |
| EAN | 5710629499882 |
| Approvals | cETLus, Proposition 65 |
| Net weight | 15.3 lb |
| Gross (shipping) weight | 16.4 lb |
| Country of origin | United States |
| HS / customs tariff code | 8413.70.2005 |
Typical Applications
Hydronic heating and chilled-water circulation • domestic hot-water recirculation • radiant floor loops • boiler primary and secondary loops • air-handling and fan-coil circuits • geothermal ground loops.
Need help? Contact ForeverPure Place for pricing, lead time, accessories, or help selecting the correct model for your application.