Skip to main content
ForeverPure Contact Us +1-408-969-2688

Myron L Ultrameter II™ 4PII-BD — Conductivity, Resistivity, TDS & Temperature, bluDock enabled

Myron L

Contact us for pricing

(No reviews yet) Write a Review
SKU:
4PII-BD
Availability:
Contact us for pricing
Brand:
Myron L
Product-Category:
Handheld Instrument
Measurement-Type:
Conductivity, Resistivity, TDS & Temperature
TECHNICAL SPECIFICATIONS: Myron L Ultrameter II™ 4PII-BD — Conductivity, Resistivity, TDS & Temperature, bluDock enabled
Identification
Model / SKU4PII-BD
BrandMyron L® Company
Product TypeUltrameter II™ handheld instrument
MeasuresConductivity, Resistivity, TDS & Temperature
Country of OriginUnited States
Measurement
Measured ParametersConductivity, resistivity, TDS, temperature
Accuracy±1% of reading (±0.1% at the calibration point)
Display4-digit LCD, values to 9999
Solution ModesKCl, NaCl and 442 Natural Water™; user-adjustable conductivity/TDS ratio
Temperature CompensationAutomatic, user adjustable to 9.99%/°C, and can be disabled
MemoryNon-volatile, up to 100 readings with date and time stamp
Physical & Power
Case / Cell MaterialVALOX®
Power9 V alkaline battery
Battery Life100 hours / 5,000 readings
Operating / Storage Temperature0-55 °C / 32-132 °F
Protection RatingIP67 / NEMA 6 — waterproof to 1 m / 3 ft
Dimensions196 × 68 × 64 mm / 7.7 × 2.7 × 2.5 in. (L × W × H)
Weight352 g / 12.4 oz (instrument)
WirelessbluDock™ installed — Bluetooth® transfer to a PC running Guardian2™ software (Windows)
What is in the box
4PII-BD instrument with bluDock option installed
bluDock™ wireless option
This is the same instrument as the 4PII with the bluDock™ module factory-installed. It transfers stored readings to a PC over Bluetooth® using Myron L’s Guardian2™ software. Guardian2 is Windows-only — there is no current macOS build. The module is internal, so the two versions look identical.
Warranty
Two (2) Year Limited Warranty on the instrument. Warranty is limited to repair or replacement at the manufacturer’s discretion and excludes damage from abuse, tampering or environmental extremes.
WHERE THIS IS USED — 10 APPLICATIONS

Myron L publishes an application bulletin for each of these. The summaries below are ours; the linked bulletins are Myron L’s own and open in a new tab.

Boilers & Cooling Towers

Facilities, HVAC, process steam

Boilers and cooling towers concentrate dissolved minerals as water boils off or evaporates, and past a certain point that causes either scale or corrosion. Myron L notes that as little as 1/8 in. of scale can cost a boiler 18% of its efficiency and a cooling-tower heat exchanger 40%. Conductivity or TDS tracks the cycles of concentration so blowdown and bleed-off happen at the right moment — enough to protect the plant, not so much that water and treatment chemicals are wasted.

Measured here: Conductivity / TDS, pH, ORP, temperature, LSI

📄 Boilers & Cooling Towers Application Bulletin (PDF)
Circuit Board Cleanliness Testing

Electronics manufacturing

Ionic residue left on a finished board degrades insulation resistance and dielectric strength. Rather than send boards to a lab, the board is rinsed in a measured volume of extract solution — 75 parts by volume of 99% isopropyl alcohol to 25 parts deionised water — and the conductivity of that extract is read directly, giving a fast production-floor check of ionic contamination historically benchmarked against MIL-P-28809. The mixture must itself read no more than 0.166 µS/cm before use, or the result means nothing.

Measured here: Conductivity, resistivity

📄 Circuit Board Cleanliness Testing Application Bulletin (PDF)
Deionized Water

Laboratory, pharmaceutical, electronics, plating

Ion-exchange resin strips cations and anions from water until its exchange capacity is spent. Because the purity of DI water is defined by what little remains dissolved in it, resistivity is the natural measurement — it climbs as purity rises and falls sharply as a bed exhausts. Monitoring resistivity continuously is what tells you to regenerate or swap a bed before off-spec water reaches the process.

Measured here: Resistivity, conductivity / TDS

📄 Deionized Water Application Bulletin (PDF)
Environmental Monitoring

Wastewater, stormwater, surface water

Discharge to waterways, to municipal sewers and increasingly stormwater runoff all sit under permit limits, and demonstrating compliance means measuring at many points rather than one. Conductivity, pH, ORP, dissolved oxygen and nitrate together characterise both the health of a receiving water and the quality of an effluent, and handheld instruments make it practical to sample where the water actually is.

Measured here: Conductivity / TDS, pH, ORP, dissolved oxygen, nitrate, temperature

📄 Environmental Monitoring Application Bulletin (PDF)
Fountain Solutions (Lithographic Printing)

Commercial printing

In lithography the dampening (fountain) solution has to be held at the right concentration: too weak and the non-image area dries out, giving tinting, scumming and blanket piling; too strong and the ink over-emulsifies, weakening colour and changing its body and flow. pH was the traditional test, but most modern fountain solutions are buffered, so pH barely moves even when strength changes a lot. Conductivity tracks concentration directly and is now the more reliable control.

Measured here: Conductivity, temperature, pH

📄 Fountain Solutions (Lithographic Printing) Application Bulletin (PDF)
Horticulture & Growing

Nurseries, greenhouses, turf, irrigation

Three on-site tests tell a grower most of what a lab would: electrical conductivity, pH and alkalinity. EC reads the total dissolved fertiliser salts, so it shows whether feed strength and soil salinity are where they should be; pH governs whether those nutrients are actually available to the plant; and alkalinity determines how strongly the irrigation water will push the growing medium’s pH over time.

Measured here: Conductivity / EC, pH, alkalinity, temperature

📄 Horticulture & Growing Application Bulletin (PDF)
Hydroponics

Controlled-environment agriculture

With no soil to buffer it, the nutrient solution is the entire root environment, and managing it is the whole job. Conductivity gives the dissolved nutrient strength and pH governs which of the seventeen required elements the roots can actually take up. Both drift as plants feed and as water evaporates, so they are checked and corrected far more often than in soil growing.

Measured here: Conductivity / TDS, pH, temperature, dissolved oxygen

📄 Hydroponics Application Bulletin (PDF)
Oxidation Reduction Potential (ORP / Redox)

Disinfection, process control, water treatment

ORP measures the strength of the oxidisers and reducers present rather than their concentration, and it is reported in millivolts with no temperature correction. That distinction matters: a chlorine residual tells you how much is there, while ORP tells you how effectively it is actually oxidising. Positive readings indicate an oxidising solution such as chlorinated water; negative readings indicate a reducing agent such as sodium sulfite.

Measured here: ORP / redox, pH, free chlorine equivalent

📄 Oxidation Reduction Potential (ORP / Redox) Application Bulletin (PDF)
Reverse Osmosis

Desalination, industrial, medical, drinking water

Conductivity is the standard way to judge RO water quality and membrane performance, because comparing feed against permeate gives percent rejection directly. ORP and pH matter for membrane life rather than product quality: membranes are attacked by oxidisers such as chlorine, bromine, ozone and peroxide, so a high ORP signals a need for pretreatment while a low one can indicate biological activity and fouling. Reading ORP on the reject stream, where concentration is highest, shows even trace oxidisers or reducers.

Measured here: Conductivity / TDS, resistivity, ORP, pH, temperature

📄 Reverse Osmosis Application Bulletin (PDF)
Textiles Manufacturing

Wet processing, dyeing, finishing

Wet spinning, sizing, desizing, scouring, bleaching, mercerisation, dyeing and printing all depend on aqueous chemistry, and pH is the primary control in every one of them — it governs how effectively oxidising and reducing agents work and how dye takes up. Holding pH, conductivity or salt concentration, ORP and temperature to target conserves chemicals and energy, keeps shade and quality consistent, and reduces the effluent load that has to be treated before discharge.

Measured here: pH, conductivity / TDS / salt concentration, ORP, temperature

📄 Textiles Manufacturing Application Bulletin (PDF)

Application areas are those in which the Myron L® Company’s own application bulletin names this instrument. Bulletins are reproduced unaltered with Myron L’s copyright notices intact. Suitability for a specific installation should be confirmed with us before purchase.

Specifications taken from the Ultrameter II Data Sheet and myronl.com, published by the Myron L® Company. Myron L reserves the right to change design, specifications and prices without notice — please confirm critical figures with us before purchase. Myron L®, Ultrameter®, Ultrapen™, UltrapenX2™, TechPro™, PoolPro™, bluDock™, Guardian2™, FCE™ and 442 Natural Water™ are trademarks of the Myron L Company. VALOX® is a registered trademark of SABIC. Bluetooth® is a registered trademark of Bluetooth SIG, Inc.