Skip to main content
ForeverPure Contact Us +1-408-969-2688

Pentair X-Flow XF64 Ultrafiltration (UF) Membrane Element, 64 m² (689 ft²), PES/PVP Hollow Fiber

Pentair

Contact us for pricing

(No reviews yet) Write a Review
SKU:
PENTAIR-XF64
Availability:
Made in the Netherlands - typical lead time 2-3 weeks EXW factory. Contact us for pricing.
Brand:
Pentair
Product-Category:
Membrane
Membrane-Type:
UF

The Pentair X-Flow XF64 is a pressurized, hollow-fiber ultrafiltration (UF) membrane element with 64 m² [689 ft²] of hydrophilic PES/PVP membrane and a 20 nm nominal pore size. It is used for reverse osmosis pretreatment, for polishing process water and treated effluent for reuse, and for potable and process water production from surface water. The XF64 installs in Pentair X-Flow 87L09 housings in a Xiga configuration, and can also be used in Pentair’s Aquaflex and X-Line systems. Made in and shipped from the Netherlands; typical lead time 2–3 weeks EXW factory. Contact us for pricing.

64 m² Membrane area (689 ft²)
20 nm Nominal pore size, PES/PVP
SDI < 3 Typical permeate; turbidity < 0.1 NTU
8.66 × 60.52 in Element OD × length (220 × 1,537.5 mm)
2–3 weeks Typical lead time, EXW factory (the Netherlands)

Datasheet & Documents

Pentair X-Flow membrane element datasheet XF64_DS_ENG_V2418 (2 pages, English). Product photos are Pentair images.

Technical Specifications

General
Manufacturer / modelPentair X-Flow XF64 ultrafiltration membrane element
Article code2272DL295A
Former namesAquaflex 64, Xiga 64, Seaflex 64, Seaguard 64 (per Pentair)
ConfigurationPressurized module, single-fiber inside-out filtration; installs vertically or horizontally
Pentair system platformsXiga, Aquaflex, X-Line
Membrane
Membrane typeHydrophilic hollow-fiber ultrafiltration, asymmetric/microporous structure
Membrane materialBlend of polyethersulfone and polyvinylpyrrolidone (PES/PVP)
Nominal pore size20 nm [0.02 µm]
Hydraulic fiber diameter0.77 mm [30.3 mil]
Effective membrane area64 m² [689 ft²]
Performance (Pentair figures)
Typical permeate qualitySDI < 3; turbidity < 0.1 NTU
Microbial reduction99.9999% of bacteria and 99.99% of viruses, by mechanical means
EPA establishment no.090374-NLD-001
Operating limits
Max. transmembrane pressure, filtration100 kPa [14.5 psi]
Max. transmembrane pressure, backwash200 kPa [29 psi]
Temperature range0–40 °C [32–104 °F]
pH, filtration2 to 12
pH, cleaning1 to 13
Pressure drop at 0.2 m/s [0.66 ft/s]16 kPa [2.3 psi] (water, 20 °C [68 °F])
Pressure drop at 0.5 m/s [1.64 ft/s]40 kPa [5.8 psi] (water, 20 °C [68 °F])
Temperature changeMax. 3 °C/min [5.4 °F/min]; avoid sudden drops
Cleaning chemical limits
Sodium hypochloriteTypical 200 ppm at ≤ 40 °C [104 °F], pH ≥ 10; max. 500 ppm; 250,000 ppm·h cumulative
Chlorine dioxideTypical 1 ppm at ≤ 40 °C [104 °F]; max. 2 ppm; 90,000 ppm·h cumulative
Hydrogen peroxideTypical 200 ppm at ≤ 40 °C [104 °F]; max. 500 ppm; 350,000 ppm·h cumulative
Combined NaOCl + ClO₂ exposure2.6 × ClO₂ ppm·h + NaOCl ppm·h, below 250,000 ppm·h
Acids and basesResistant to HCl, HNO₃, H₂SO₄, H₃PO₄, acetic and citric acid; NaOH and KOH below 4%
Dimensions
Element outside diameter (D0)220.0 mm [8.66 in]
Element length (L0)1,537.5 mm [60.52 in]
Permeate connection (d0)42.6 mm [1.68 in]
Materials of construction
Element housingPVC, white
Flow distributorPVC/PVC
PottingPolyurethane (PU) resin
MembranePES/PVP
Weight
Dry elementapprox. 34 kg [75 lb]
Element filled with waterapprox. 66 kg [145 lb]
Storage
As suppliedVacuum-sealed bag; preserved with 20 wt% glycerine and 1 wt% sodium metabisulfite
Storage temperature0–40 °C [32–104 °F], dry, ventilated, out of direct sunlight
Shelf lifeMax. 6 months from ready-for-delivery ex works (Pentair)
Supply
Made inThe Netherlands
Ships fromThe Netherlands
Typical lead time2–3 weeks EXW factory
PriceOn request, quoted per project

Housing Compatibility: 87L09 in a Xiga Configuration

Pentair supplies the XF64 with 87L09 fiberglass UF housings arranged in a Xiga configuration, Pentair’s horizontal rack layout for large UF plants in a small footprint. Key 87L09 ratings from Pentair’s housing drawing:

HousingPentair X-Flow 87L09 non-coded fiberglass UF membrane housing
Designed forX-Flow Aquaflex 55/57/64 elements (XF64 was formerly Aquaflex 64); interfacing hardware for the specified element is supplied with the housing
Design pressure90 psi [0.62 MPa]
Temperature32–104 °F [0–40 °C]
ShellFilament-wound epoxy/glass composite
Feed / concentrate ports2.5 in IPS grooved side ports
Permeate port2.5 in IPS grooved, in the end closure

Housings, racks and replacement 2.5 in feed/concentrate ports and seals for 87L09 housings are quoted separately. Mount and pipe the housings to Pentair’s installation precautions: use flexible grooved couplings at the side ports, align the ports with the header, and support the piping so the housing shell carries no bending load.

Where the XF64 Fits

RO and SWRO pretreatmentNear-total removal of suspended solids and silt protects downstream RO elements from fouling.
Effluent polishing and reuseA barrier for turbidity and microbiology ahead of high-grade reuse.
Potable waterRejection of viruses and chlorine-resistant organisms such as Cryptosporidium and Giardia.
Process waterSolids-free permeate, used directly or fed to RO where dissolved solids must come down.

Permeate flux and recovery depend on the feed water. We prepare a UF design for your water analysis and flow before quoting.

Frequently Asked Questions

What is the XF64 used for?
The XF64 is an ultrafiltration (UF) element for pretreatment ahead of reverse osmosis (including large seawater RO plants), polishing of process water and treated effluent for reuse, and potable and process water from surface water. It removes suspended solids, colloids, bacteria and viruses, giving RO a feed with an SDI below 3 and turbidity below 0.1 NTU (typical, per Pentair).
Does UF remove dissolved salts or hardness?
No. A 20 nm UF membrane removes particles, colloids and microorganisms, but dissolved salts, hardness and most dissolved organics pass through. Where salinity has to come down, the UF permeate feeds a downstream RO system.
Which housing does the XF64 go in?
Pentair supplies the XF64 with 87L09 fiberglass UF housings in a Xiga configuration. The 87L09 is designed for X-Flow Aquaflex 55/57/64 elements, rated 90 psi [0.62 MPa] and 32–104 °F [0–40 °C], with 2.5 in IPS grooved feed/concentrate and permeate ports. The XF64 can also be used in Pentair’s Aquaflex and X-Line systems; tell us your rack or housing details and we will confirm the fit.
Does it replace Aquaflex 64, Xiga 64, Seaflex 64 or Seaguard 64?
Pentair states that the XF64 was formerly known as Aquaflex 64, Xiga 64, Seaflex 64 and Seaguard 64. To replace elements in an existing plant, send us the element label or model, the housing model and serial numbers, and the quantity, and we will confirm the replacement with Pentair before you order.
What cleaning chemicals and limits apply?
Per Pentair’s datasheet: sodium hypochlorite typically 200 ppm (max. 500 ppm, 250,000 ppm·h cumulative), chlorine dioxide typically 1 ppm (max. 2 ppm), hydrogen peroxide typically 200 ppm (max. 500 ppm), at up to 40 °C [104 °F]. Keep pH between 2 and 12 in filtration and between 1 and 13 in cleaning. Keep oxidant exposure to a minimum, and store the membranes free of oxidant whenever the plant is stopped.
Where is it made, and what is the lead time?
The XF64 is made in the Netherlands and ships from the Netherlands. Typical lead time is 2–3 weeks EXW factory. Freight, import clearance and delivery to your site are quoted separately, and we confirm the lead time on each quotation.
Why is there no price?
UF elements are quoted per project, because the quantity, the housings and the rack arrangement (vertical, horizontal or X-Line) all change the scope. Send us your requirements and we will prepare a quotation.
How should I store new elements?
Keep them in the original vacuum-sealed bags at 0–40 °C [32–104 °F], in a dry, ventilated place away from heat and direct sunlight. Pentair limits shelf life to 6 months from the date the elements are ready for delivery ex works, so plan installation and commissioning as soon as possible after delivery.
What do you need from me to quote or size a UF system?
The feed water source (surface, well, seawater or treated effluent), a water analysis (at least turbidity, TSS and TOC), the required permeate flow, the water temperature range, what the UF permeate feeds (RO, reuse or potable), and your delivery address. For a replacement, add the existing element and housing models and serial numbers.
Request a quote. Call +1-408-969-2688 ext. 117, email sales@ForeverPure.com or use our contact form. Tell us your feed water, required permeate flow and delivery location, and we will quote the elements, housings and freight.

More from ForeverPure: Pentair X-Flow XF75 (75 m², vertical) · RO, UF & NF membranes · membrane housings · CodeLine membrane vessels · all Pentair products

Source: Pentair X-Flow membrane element datasheet XF64 (XF64_DS_ENG_V2418, © 2024 Pentair), the X-Flow XF64 product page at xflow.pentair.com, and Pentair’s 87L09 housing drawing. Figures are Pentair’s typical values and guidelines, not a performance guarantee; confirm against Pentair’s current datasheet before purchase. Pentair, X-Flow, Xiga, Aquaflex and X-Line are trademarks of Pentair.

\n